How to control vacuum packed products that have very little or no air inside?
Optional Kit for Vacuum Packed Products
Needle: allows to inject pressurized air inside the packaging
Seal Pad: allows to protect the packaging during the test and to avoid leaking around the needle
Pressure Regulator: allows to set the pressure up to 1 bar (15 psi)
Clamp: allows to make sure the lid is closed during the test and that the sample is fully immerse.
This option is available with any of our control systems:
How can we solve this problem?
We need to inject pressurized air.
1. Connect the needle
2. Stick the seal pad
3. Insert needle through the pad
4. Place sample inside water bath.
5. Close the lid
6. Switch to pressure mode
7. Press START button
8. Wait and observe
Bubble = Leak
If you see any bubble coming out from the sample, that means there is a leak.
This testing method allows to determine the exact position of the leakage.
So you know which part of the packing process you have to focus to fix the problem.